Skip to main content

HOW TO CONTROL UKG IN RINGFRAME

CONTROL UKG IN RINGFRAME :-

1)Working with Lower Ring frame TM

2) Working with Lesser Ring dia

3) Lift conversation

4) Correct usage of combination of RF empty Tube vs Spindle height (20 mm )

5) Maintain correct speed curve, high speed reach before 25% of final length of the yarn to be produced

6) Usage of Higher efficiency of Main motor(94.5%)

7) Avoid Light doffs and check doff has to fall at set doff length meter

8) Usage of Energy efficient Fan motor( Less weight Fans )

9) Instead of continuous running of OHTC from one to another end of the Ringframe, every reversal attend of the machine, We can stop OHTC for 1-5 minutes

10) Usage of light weight cops in ringframe

11) Maintain proper schedule of Spindles replacing

12) Maintain proper Jockey pulley servicing and greasing

13) Working with short strech conversation

14) Working with energy saving spindle tapes

15) Maintain perfect schedules of motor greasing and other elements bearings

The following precautions to be taken while conducting power study at Ringframe :-

1) No idles spindle running in the machine

2) Avoid Light doffs in the machine

3) Ensure speed pattern running with Regular one or not

4) Collect correct weight of pneumafil waste

5) Avoid any changes in the Ringframe

Comments

Popular posts from this blog

RKM

RKM INFORMATION This can be expressed by the “Length of yarn in km” at which yarn will break of its own weight”. This is equivalent to breaking load in g/tex. RKM is the short expression for “Reisskilometer” – “Breaking-kilometre”, which is an unit out of date. E.g.: a Cotton-yarn with 15 RKM means, it would break of its own weight, if you wind off 15 km of the yarn and hang it up in 15 km. Nowadays it is common practice, to use the unit Centi-Newton per Tex (cN/Tex) or gram-force per Tex (gf/Tex). RKM and cN/Tex or gf/Tex are practically the same (a slight difference would be there)   SINGLE YARN STRENGTH (Breaking force) :  This is the force required to break a strand of single yarn. It is expressing Centi-Newton (cN).     STRENGTH (Tenacity) : The Tensile Strength expressed as force per unit linear density is called Tenacity. This is normally expressed as gram force per tex (gf/tex).   CSP (Count Strength Product) : CSP, the bundle strength...

HOW TO CALCULATE YARN DIAMETER

HOW TO CALCULATE YARN DIAMETER     The diameter of  yarn can be calculated by 1divded 28 Square root of Count is called as Diameter of yarn in Per inch. Example :-      Count - 20s & 40s Formula:- 1/28 Square root of  Count = Diameter of inch 28Square root of  20 = 125.22 1/125.22 = 0.007986 Per inch 0.007986 x 25.4 = 0.203 So the diameter of yarn is 0.203 Formula:- 1/28 Square root of  Count = Diameter of inch 28Square root of  40 = 177.088 1/177.088 = 0.005647 Per inch 0.005647  x  25.4 = 0.203 So the diameter of yarn is 0.143 Then 1Divded 28 Square root of count why we apply Here?  

40s CONVERSION FACTOR PRODUCTION

40s CONVERSION FACTOR PRODUCTION:-      Here we give  the  40s CONVERSION FACTOR(s) FOR PRODUCTION DEPARTMENT  as SITRA newly released details given below. COUNT                                               CORRECTION FACTOR 40s COMBED COMPACT                    : 0.807 41s COMBED COMPACT                    : 0.837 50s COMBED COMPACT                    : 1.127 51s COMBED COMPACT                    : 1.185 57s COMBED COMPACT HOISERY   : 1.207 60s COMBED COMPACT                    : 1.503 61s COMBED COMPACT                    : 1.541